Arizona Boiler offers training for individuals and for your employees.
 
EMERGENCY

We now offer two great courses for the price of one.
  AUTO FLAME
  BOILERS
 

Please call for our next class schedule and to register
(623) 979-3301

 
     
Covering the following:
  • Arizona State & Federal Usage Codes
  • Burner Fundamentals
  • Safety Controls and Limits
    1. Function and Operation
    2. Testing
  • Flame Safeguard Fundamentals
  • Testing - AS PER STATE CODE
  • Boiler Lighting Procedures
  • Boiler Feed Water
  • Boiler Blowdown Procedures
  • Safety Procedures to Follow
  • Low water Condition
  • Safe Shut Down Procedures
  • Cost Savings-Increase Fuel Efficiency
  • Code Preventive Maintenance
  • This course is designed to assist the user or operator of a boiler to comply with the state requirement.
  • The course will aid in setting up a preventive maintenance program for your boiler.
  • You will be taught how to conduct the tests required for various boiler/burner components as listed by our state boiler
(ARIZONA BOILER REGULATIONS - R4-13-406 - PAGE 27)
  In addition to the requirements of subsection (A), an owner, user, or operator of a boiler constructed under the ASME Code, Sections I, II, IV, V, or IX Shall comply with the following preventive maintenance schedule if the boiler contains the component or system listed.
 
  1. On a daily basis, the owner, user, or operator shall:
    1. Test the low-water fuel cutoff and alarm, and
    2. Check the burner flame for proper combustion.
  2. On a weekly basis, the owner, user, or operator shall:
    1. Check for proper ignition, and
    2. Check the flame failure detection system.
  3. On a monthly basis, the owner, user, or operator shall:
    1. Test all fan and air pressure interlocks,
    2. Check the main burner safety shutoff valve,
    3. Check the low fire start switch
    4. Test fuel pressure and temperature interlocks of oil-fired units, and
    5. Test the high and low fuel pressure switch of gas-fired units.
  4. Every 6 months, the owner, user, or operator shall:
    1. Inspect burner components;
    2. Check flame failure system components, such as vacuum tubes, amplifier, and relays;
    3. Check wiring of all interlocks and shutoff valves
    4. Recalibrate all indicating and recording gauges; and
    5. Check steam and blowdown piping and valves.
  5. Annually, the owner, user, or operator shall:
    1. Replace vacuum tubes, scanners, or flame rods in the flame failure system according to the manufacturer's instructions;
    2. Check all coils and diaphragms; and
    3. Test operating parts of all safety shutoff and control valves.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
       
 

Please call for our next class schedule and to register
(623) 979-3301

 
 
  OIL HEATERS
  TANKS

EMERGENCY

  SERVICE PACKAGES
  FUEL CONVERSION
  "R" STAMP REPAIR
  "S" STAMP   "S" STAMP
  BOILER TRAINING
  ASBESTOS REMOVAL
You May Send
Correspondence
and Visit Our
Facility at:

8282 N. 75th Ave
Peoria, AZ 85345
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           
           
   

Arizona Boiler Company, Inc.     8282 N. 75th Ave; Peoria, AZ 85345

    Phone: 623-979-330      Toll Free: 1-800-676-0301      Fax: 623-979-3666
    Arizona License # R0C072282 and # R0C0076936